            Information for general use:

            • /cx bzw. /vx stands for the Controller/Virtual Drive Number.
            • /ex bzw. /sx stands for the Enclosure/Slot ID.

            Firmware Update

            sudo storcli /cx download file=/path/to/firmware.rom

            Information on the Controller and Configuration

            sudo storcli /cx show all

            Activation of Features (e.g. CacheCade, FastPath,...)

             sudo storcli /cx set aso key=AAAAAAAABBBBBBBBCCCCCCCC

            Information on the existing hard drives and their status (IDs,...)

            sudo storcli /cx /eall /sall show (all)

            Information on the existing virtual drives and their status

            sudo storcli /cx /vall show (all)

            View current status of all rebuilds

            sudo storcli /cx /eall /sall show rebuild

            Creating a Virtual Drive

            sudo storcli /cx add vd type=[RAID0(r0)|RAID1(r1)|...] drives=[EnclosureID:SlotID|:SlotID-SlotID|:SlotID,SlotID]

            Example:

            sudo storcli /cx add vd type=r1 drives=252:0-2

            Initializing a VD

            sudo storcli /cx/vx start init (force)

            Progress can be monitored using the following command:

            sudo storcli /cx/vx show init

            Creating a CacheCade device

            sudo storcli /cx add vd cc type=r[0,1,10] drives=[EnclosureID:SlotID|:SlotID-SlotID|:SlotID,SlotID]  WT|WB (assignvds=0,1,2)

            Example:

            sudo storcli /c0 add vd cc type=r1 drives=252:2-3 WB

            CacheCade activation/deactivation

            sudo storcli /cx/[vx|vall] set ssdCaching=[on|off]

            Example:

            sudo storcli /c0/v1 set ssdCaching=on

            Removing a CacheCade device

            sudo storcli /cx/vx del cc

            Removing a VD

            sudo storcli /cx/vx del (force)

            Incorporating an improperly removed device

            If an improperly removed device is reconnected to the RAID controller it will be recognized as UBAD (Unconfigured Bad).

            sudo storcli /c0 /eall /sall show
            Controller = 0
            Status = Success
            Description = Show Drive Information Succeeded.
             
             
            Drive Information :
            =================
             
            -------------------------------------------------------------------------------
            EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                  Sp 
            -------------------------------------------------------------------------------
            252:0     7 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
            252:1     6 Onln   1  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
            252:2     5 UGood  -  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
            252:3     4 UBad   - 223.062 GB SATA SSD N   N  512B INTEL SSDSC2CW240A3    U  
            -------------------------------------------------------------------------------
             
            EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
            DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
            UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
            Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
            SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
            UGUnsp-Unsupported

            This status must be changed to UGOOD.

            sudo storcli /cx /ex /sx set good
            Controller = 0
            Status = Success
            Description = Show Drive Information Succeeded.
             
             
            Drive Information :
            =================
             
            -------------------------------------------------------------------------------
            EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                  Sp 
            -------------------------------------------------------------------------------
            252:0     7 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
            252:1     6 Onln   1  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
            252:2     5 UGood  -  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
            252:3     4 UGood  F 223.062 GB SATA SSD N   N  512B INTEL SSDSC2CW240A3    U  
            -------------------------------------------------------------------------------
             
            EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
            DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
            UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
            Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
            SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
            UGUnsp-Unsupported

            Now the device is foreign in the pool

            sudo storcli /cx /fall show
            Controller = 0
            Status = Success
            Description = Operation on foreign configuration Succeeded
             
             
            FOREIGN CONFIGURATION :
            =====================
             
            ----------------------------------------
            DG EID:Slot Type State       Size NoVDs 
            ----------------------------------------
             0 -        Cac0 Frgn  223.062 GB     1 
            ----------------------------------------
             
            NoVDs - Number of VDs in disk group|DG - Diskgroup
            Total foreign drive groups = 1

            Now it can be included in the configuration.

            sudo storcli /cx /fall import

            If the device was part of a RAID a rebuild is performed automatically (see the state: Rbld in the overview). The following command progress can be monitored:

            sudo storcli /cx /ex /sx show rebuild

             